HAN Huili, PENG Qijun, ZHU Denglin. Failure Analysis of the Junction Box Used for Photovoltaic Module Serviced Outdoor[J]. Journal of Xinyang Normal University (Natural Science Edition), 2024, 37(2): 165-168. DOI: 10.3969/j.issn.1003-0972.2024.02.005
Citation: HAN Huili, PENG Qijun, ZHU Denglin. Failure Analysis of the Junction Box Used for Photovoltaic Module Serviced Outdoor[J]. Journal of Xinyang Normal University (Natural Science Edition), 2024, 37(2): 165-168. DOI: 10.3969/j.issn.1003-0972.2024.02.005

Failure Analysis of the Junction Box Used for Photovoltaic Module Serviced Outdoor

  • The failure phenomenon of the junction box used for photovoltaic modules in a large-scale photovoltaic power station was investigated. This investigation involved the visual inspection of the junction box, analysis of its voltage-current (I-V) characteristics, and further dissection testing and analysis. Ultimately, the burn marks were discovered on the protection ring position of the diode’s surface after dissection. The failure of the junction box was attributed to diode breakdown induced by lightnin strike.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return